Siemens Sinamics S120 Getting Started page 53

With starter
Hide thumbs Also See for Sinamics S120:
Table of Contents

Advertisement

6. Activate the check box "Enable signals".
The symbols
7. Enter a suitable speed for the motor in input field "n = ", e.g. "1,000."
Image 7-8
8. Click on the symbol
The motor accelerates to the selected example speed of 1000 rpm. The "Enables
available" LED lights up green
Switching off the drive
1. To switch-off the motor, click on the
The drive coasts to a standstill.
2. Click on the "Give up control priority!" button to return the control priority.
3. Confirm the following "Return control priority" prompt with "Yes."
4. Go to the menu items "Project > Disconnect from target system" to end the
communication between the PG/PC and the Control Unit.
5. Go to the menu items "Project > Save" to save the example project to the local hard disk
of the PG/PC.
STARTER Getting Started
Getting Started, (GS1) 07/2016, 6SL3097-4AG00-0BP4
and
are active.
Control panel motor running
.
.
symbol.
Commissioning a drive
53