Appendix
A.2 Restoring factory settings
3. Activate the check box " S120_CU320_2_DP ", and click on "OK."
The PG/PC establishes the link to the Control Unit. It then performs an "Online/offline
comparison". The result is displayed in the following dialog "Online/offline comparison".
Example:
Image A-2
4. Click on the "Close" button.
5. Select the drive object "S120_CU320_2_DP" in the project navigator.
6. With the right mouse button, select the shortcut menu "Target device > Restore factory
settings."
7. Confirm the query with "OK".
The PG/PC sets the drive parameters to their factory settings.
The new status is automatically transferred to the Control Unit memory card using the
function "Copy RAM to ROM".
8. Select the drive unit in the project navigator and go to the shortcut menu "Target device >
Copy RAM to ROM."
The factory settings have now been restored: the drive is in a defined basic state.