Powering the Machine

Setting the Operating Voltage
The machine can operate with a 115 V or 230 V supply
voltage. The voltage block determines the operating
voltage of the machine
steps to change the operating voltage:
1.
Park the machine on level ground.
2.
Stop the motor and unplug the machine.
3.
Remove the 2 screws securing the voltage block
to the motor.
4.
Remove the voltage block from the motor, rotate
the voltage block 180 degrees and plug it back
into the motor.
5.
Secure the voltage plug to the motor with the 2
screws that you previously removed.
Note:
Use the instructions on the voltage block to
determine the voltage block setting.
Connecting to a Power Source
DANGER
Contact with water while operating the
product could cause electric shock, causing
injury or death.
• Do not handle the plug or the machine with
wet hands or while standing in water.
• Use only an extension cord recommended
for outdoor cold-weather use.
Important:
Check the extension cord frequently
during use for holes or cracks in the insulation.
Do not use a damaged cord. Do not run the cord
through standing water or wet grass.
Important:
Use only extension cords with
terminals and sockets for the live, neutral, and
ground wires.
Important:
Connect the machine to only
a receptacle with live, neutral, and ground
connections.
Important:
The connecting wires or extension
cord should be as short as possible and in 1 piece.
24).
(Figure
10). Use the following
To reduce the risk of electric shock, this machine
has a polarized plug (unique blade shapes and
widths). Use only a polarized plug and socket that is
compliant with NEMA specifications and an extension
cord that is UL-listed (CSA certified in Canada) and
recommended for outdoor use. A polarized plug will fit
in a polarized cord only 1 way. If the plug does not fit
fully into the cord, turn the cord. If it still does not fit,
purchase an appropriate extension cord. If you have a
polarized extension cord and the extension cord plug
does not fit fully into the wall receptacle, turn the plug.
If it still does not fit, contact a qualified electrician to
install the proper outlet. Do not change the machine
plug or extension-cord plug in any way.
Note:
The machine uses a twist-locking plug.
Extension Cords
Length
15.2 m (50 ft)
22.8 m (75 ft)
30.4 m (100 ft)
Note:
Do not use an extension cord over 30.4 m
(100 ft) long.
20
Wire Gauge
10 AWG
10 AWG
8 AWG