2 SYSTEM CONFIGURATION
Number of I/O occupying points
Internal current consumption(5VDC)[A]
Exterior dimensions [mm(inch)]
Mass [kg]
No.
Name
9)
RIO2 connector
Rotary switch for station
number setting
10)
8
11) Serial number display
(2) Performance specifications
(a) Module specifications
Item
RIO communication for Motion CPU
(For connection to Q173DSXY installed on the right)
Set station number of safety signal module.
(Note)
Setting
0
Station number 1 (Module 1)
1
Station number 2 (Module 2)
2
Station number 3 (Module 3)
(Note): Do not set other than the above setting.
Display the serial number described on the rating plate.
32 points (I/O allocation: I/O mix, 32 points)
0.2 (TYP. All points ON)
98(H) 27.4(W) 90(D)
(3.86(H) 1.08(W) 3.54(D))
2 - 81
Application
Station number
Specifications
0.15