Figure 84. 3.5-inch-drive backplane installation
Step 1.
Connect the cables to the backplane.
Step 2.
Align the backplane with the chassis and lower it into the chassis. Then, put the backplane into
place with it leaning backward slightly.
Step 3.
Rotate the backplane to vertical position to ensure that the four hooks on the chassis pass through
the corresponding holes in the backplane. Then, slide the new backplane as shown until it is
secured into place.
Step 4.
Apply the drive bay label based on the type of the installed backplanes. The drive bay label comes
with each type of the supported drive backplane:
• 0–7
Apply this label to the chassis if an 8-bay backplane is installed.
• 0–11
Apply this label to the chassis if a 12-bay backplane is installed.
• 0–11 (NVMe)
Apply this label to the chassis if an AnyBay 12-bay backplane is installed.
Note: NVMe drives are supported in drive bays 8–11.
.
Chapter 3
Server hardware setup
157