Step 1.
Align the mounting stud on the system board with the corresponding hole in the rear hot-swap
drive assembly. Meanwhile, align the rear of the rear hot-swap drive assembly with the
corresponding rail guides in the rear of the chassis. Then, carefully press the rear hot-swap drive
assembly straight down into the chassis until it is fully seated.
Figure 86. Rear hot-swap drive assembly installation
Step 2.
Connect the signal cable to the rear hot-swap drive assembly and the RAID adapter. See "Internal
cable routing" on page 35.
After installing the rear hot-swap drive assembly, you can install hot-swap drives to the assembly. See
"Install a hot-swap drive" on page 190.

Install the RAID adapter

Use this information to install the RAID adapter in the RAID adapter slot on the system board.
"Read the
installation
Guidelines" on
page 126
Ensure that you follow the installation order if you install more than one RAID adapter:
• The RAID adapter slot on the system board
• The PCIe slot 4 on the system board if the serial port module is not installed
• A PCIe slot on the riser card
Notes:
"Power off
the server for
this task" on
page 194
"ATTENTION:
Static Sensitive Device
Ground package before opening"
on page 127
.
Chapter 3
Server hardware setup
159