Motor/Brake Connection - Siemens SINAMICS S120 Equipment Manual

Booksize power sections cold plate
Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Motor Modules with Cold Plate
7.3 Interface description
1)
2)
Fan
1) Required if the Safety function is active
2) Additionally for motor modules 132 A to 200 A
3) Contact via shield plate
Figure 7-3
Connection example of Single Motor Modules 45 A to 200 A
7.3.3

Motor/brake connection

Table 7-1
Terminal block X1/X2 Motor Modules 3 A to 30 A and 2x3 A to 2x18 A
Terminal
U (U2)
V (V2)
W (W2)
+ (BR+)
- (BR-)
PE connection
1 for ring cable lugs to DIN 46234
7-6
Motor module
+
M
DCP
DCN
X21
1
+Temp
2
-Temp
3
EP +24 V
4
EP M1
X12
1
+
2
-
Technical specifications
Motor connection
Brake connection
Threaded hole M5/3 Nm
X200
X201
X202
DRIVE-CLiQ socket 2
READY
U2
DC LINK
V2
W2
X11
BR+
BR-
1
Equipment Manual Booksize Cold-Plate Power Sections
Manual, (GH4), Edition 06.2005, 6SL3097-2AJ00-0BP2
+
M
DCP
DCN
I
M
~
3
1
2
3)
mm_large_connection_example.vsd