Technical Specifications

7.6
Table 7-8
Technical specifications for Motor Modules with cold-plate cooling (3 A - 30 A)
Voltage
Power supply:
DC link voltage
Electronics power supply
Output voltage
Overvoltage tripping
Undervoltage tripping
Electronics current consumption at 24 V
DC link busbar current carrying capacity
24 V busbar current carrying capacity
Rated output current
Base load current I
base
Intermittent duty current l
Peak current
Rated power
(with DC link voltage of 600 V
frequency of 4 kHz)
Max. pulse frequency without derating
Max. pulse frequency with derating
Max. permissible heat sink temperature
Max. ambient temperature without derating
Max. ambient temperature with derating
DC link capacitance
Efficiency η (4 kHz)
Weight
Equipment Manual Booksize Cold-Plate Power Sections
Manual, (GH4), Edition 06.2005, 6SL3097-2AJ00-0BP2
6SL3126-1TE 13-0AA0
V
V
V
V
V
A
A
A
A
A
40%
A
S6
A
kW
and clock
DC
kHz
kHz
°C
°C
°C
μF
kg
DC
DC
ACrms
DC
DC
DC
100
DC
20
DC
3
ACrms(In)
2.6
3.5
ACrms(Is6)
6
ACrms(Imax)
1.6
70
110
0.97
4.2
Motor Modules with Cold Plate
7.6 Technical Specifications
15-0AA0
21-0AA0
21-8AA0
510 –750
24 (20.4 – 28.8)
0 - 0.67 x DC link voltage
820 ± 2%
380
See Cabinet Design and EMC
100
100
100
20
20
20
5
9
18
4.3
7.7
15.3
6
10
24
10
18
36
2.7
4.8
9.7
4
16
70
70
75
40
55
110
110
220
0.97
0.97
0.97
4.2
4.5
4.5
23-0AA0
100
20
30
25.5
40
56
16
70
710
0.97
6.1
7-15