Active line modules with cold plate
5.6 Technical Specifications
Power factor
Efficiency
Weight
Power loss
1) The specified values apply for 380 V
2) The specified rated power values/currents can only be achieved if direct liquid cooling is used. Derating will occur if installed on an external
heat sink. At a temperature of 40 °C at the interface to the power section, 80% derating occurs for 6SL3136-7TE 28-0AAx and 70% for
6SL3136-7TE 31-2AAx
Rated duty cycles of Active Line Modules
Figure 5-5
5-14
6SL3136-7TE
21-6AAx
cosϕ
η
0.98
kg
6.1
Rated duty cycles of Active Line Modules
23-6AAx
1
1
0.98
10.2
See Cabinet Design and EMC
Equipment Manual Booksize Cold-Plate Power Sections
Manual, (GH4), Edition 06.2005, 6SL3097-2AJ00-0BP2
25-5AAx
28-0AAx
1
1
0.98
0.98
13.8
20.3
31-2AAx
2)
2)
1
0.98
20.4