Technical Specifications - Siemens SINAMICS S120 Equipment Manual

Booksize power sections cold plate
Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

5.6

Technical Specifications

5.6
Table 5-8
Technical specifications for Active Line Modules with cold-plate cooling
Rated power
Connection voltages:
Line voltage
Line frequency
Electronics power supply
DC link voltage
Overvoltage tripping
Undervoltage tripping
DC link busbar current
carrying capacity
24 V busbar
current carrying capacity
Electronics current
consumption
Power:
Rated power (S1)
Power rating
(S6-40%)
Peak power rating
Regenerative feedback:
Continuous feedback
power rating Peak
feedback power rating
Supply currents:
at 380 V
AC
at 480 V
/ 528 V
AC
AC
at 480 V; S6-40%
Peak current
(at 400 V
/ 480 V
)
AC
AC
Output currents
at 600 V
:
DC
Rated current
at S6-40%
Peak current
Max. permissible heat
sink temperature
Max. ambient temperature
without derating
Max. ambient temperature
with derating
DC link capacitance
Charging limit
Equipment Manual Booksize Cold-Plate Power Sections
Manual, (GH4), Edition 06.2005, 6SL3097-2AJ00-0BP2
6SL3136-7TE
21-6AAx
kW
16
V
ACrms
Hz
V
DC
V
DC
V
DC
V
DC
A
100
ACrms
A
20
ACrms
A
DC
kW (Pn)
16
kW (Ps6)
21
kW (Pmax)
35
kW
16
kW
35
A
26
AC
A
21 / 19
AC
A
AC
27
A
AC
54 / 45
A
27
DC
A
DC
35
A
DC
59
°C
70
°C
40
°C
55
μF
710
μF
20 000
23-6AAx
25-5AAx
36
55
3 AC 380 – 10% to 3 AC 480 + 10% (-15% < 1 min)
47 to 63
24 (20.4 – 28.8)
510 – 750
820 ± 2%
360 ± 2%
100
20
See Cabinet Design and EMC.
36
47
70
36
70
58
46 / 42
70 / 64
60
107 / 89
139 / 116
60
79
117
70
40
55
1410
1880
20 000
20 000
Active line modules with cold plate
5.6 Technical Specifications
28-0AAx
2)
80
200
200
20
20
55
80
71
106
91
131
55
80
91
131
88
128
102 / 93
92
134
200 / 222
92
134
121
176
152
195
78
70
40
40
55
55
2820
20 000
31-2AAx
2)
120
200
20
120
158
175
120
175
192
152 / 139
201
267 / 222
200
244
292
75
40
55
3760
20 000
5-13

Advertisement

Table of Contents
loading

Table of Contents