Siemens SINAMICS S120 Equipment Manual page 117

Booksize power sections cold plate
Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Table 7-10
Technical specifications for Double Motor Modules with cold-plate cooling (2x3 to 2 x 18A)
Voltage
Power supply:
DC link voltage
Electronics power supply
Output voltage
Overvoltage tripping
Undervoltage tripping
Electronics current consumption at 24 V
DC link busbar current carrying capacity
24 V busbar current carrying capacity
Rated output current
Base load current I
base
Intermittent duty current l
Peak current
Rated power
(with DC link voltage of 600 V
frequency of 4 kHz)
Max. pulse frequency without derating
Max. pulse frequency with derating
Max. permissible heat sink temperature
Max. ambient temperature without derating
Max. ambient temperature with derating
DC link capacitance
Efficiency η (4 kHz)
Weight
Equipment Manual Booksize Cold-Plate Power Sections
Manual, (GH4), Edition 06.2005, 6SL3097-2AJ00-0BP2
6SL3126-2TE
V
V
V
V
V
A
A
A
A
A
40%
A
S6
A
kW
and clock
DC
kHz
kHz
°C
°C
°C
μF
kg
13-0AA0
DC
DC
ACrms
DC
DC
DC
100
DC
20
DC
2x3
ACrms(In)
2x2.6
2x3.5
ACrms(Is6)
2x6
ACrms(Imax)
1.6
75
110
0.97
4.5
Motor Modules with Cold Plate
7.6 Technical Specifications
15-0AA0
21-0AA0
510 –750
24 (20.4 – 28.8)
0 - 480
820 ± 2%
380
See "Booksize Cabinet Design"
100
100
20
20
2x5
2x9
2x4.3
2x7.7
2x6
2x10
2x10
2x18
2.7
4.8
4
16
75
85
40
55
220
220
0.97
0.97
4.5
4.5
21-8AA0
100
20
2x18
2x15.3
2x24
2x36
9.7
80
705
0.97
5.9
7-17