Offset Adjustment - Siemens SINUMERIK 840D Description Of Functions

Hla module
Hide thumbs Also See for SINUMERIK 840D:
Table of Contents

Advertisement

3 Start-Up
3.9 Fine adjustment and optimization
Definition of travel
direction in NC
(Step 3)
Cancel
manipulated
voltage
limitation
3.9.2

Offset adjustment

Offset of pressure
sensors
3-66
SINUMERIK 840D/SIMODRIVE 611 digital Descr. of Functions HLA Module (FBHLA) – 04.00 Edition
The positive direction of travel of the machine is defined by the user.
With adjustment of travel direction with setpoint MD 32100: AX_MOTION_DIR.
Step 3
(define travel direction of machine)
Traverse with JOG key
(override approx. 10%)
Does cylinder move
in the set direction ?
yes
End
Fig. 3-19
Start-up flow chart, definition of travel direction in NC
The setpoint limitation must be set in MD 5475: OUTPUT_VOLTAGE_LIMIT to
10 V.
Note
Only in combination with pressure sensing function.
Condition:
Sensors are pressure-free!
Objective:
The pressure display should be 0 at 0 pressure.
Adjustment:
S
MD 5650: Set DIAGNOSIS_CONTROL_FLAGS bit 12 (cancelled automati-
cally after 2 s).
S
Pressure sensor A:
MD 5551: PRESSURE_SENS_A_OFFS is automatically adjusted.
S
Pressure sensor B:
MD 5553: PRESSURE_SENS_B_OFFS is automatically adjusted.
The display for the two pressures (MD 5704, MD 5705) should then show
about 0.0 bar.
no
MD 32100: Change AX_MOTION_DIR
(travel direction of machine)
 Siemens AG 2000. All rights reserved