How to make Settings
!
Important
All settings are necessary, otherwise faultless operation is not possible. Please follow the se-
quence described above!
M PAW-VP380L – U-200PZH2E8 (PACi R32)
Indoor Unit Tank detailed settings; Remote controller CZ-RTC5B
i
Note
"DN" codes 10 & 11 must be set first.
"DN" 15 display temperature sensor TA, E1, E2, E3*, BL* change 0022 -> 0031
8
* to be purchased separately
Outdoor unit detailed settings by CZ-RTC2/4
64
Parameter
Default
"DN" code
value
10
0006
11
0015
06
0004
0b
0002
0C
0000
0d
0000
15
0022
16
0000
1F
0000
20
0000
21
0030
22
0018
28
0001
2C
0000
2d
0008
Parameter
Default
"DN" code
value
7
000
42
002
4b
001
4E
000
4F
000
A5
000
New value
Explanation
to set
0031
Unit Type
0021
Capacity code
0000
Inlet temperature shift in heating mode.
0001
EXCT setting
0001
Heating preparation display
0001
Cool/ Heat auto
0022
Temperature sensors
0000
Fan speed adjustment
0015
Cooling upper limit 15°C
0005
Cooling lower limit 5°C
0055
Heating upper limit 55°C
0035
Heating lower limit 35°C
0001
Automatic restart after power failure activated
0006
Expansion valve setting
0010
Operation mode Cooling and Heating
New value
Explanation
to set
001
Specific tank setting
000
Tank offset
001
Specific tank setting
Condensation temperature minimum
005
shift in heating
Condensation temperature maximum
005
shift in heating
-04
Frost adherence temperature
Check and adjust
Check and adjust
DHW PAW-VP - Installation manual – 2020-05