Panasonic PAW-VP1000LDHW Installation Manual page 79

Air-to-water heat pump systems, domestic hot water system for r410a and r32 use
Hide thumbs Also See for PAW-VP1000LDHW:
Table of Contents

Advertisement

Also, the other information can be seen on the display. All reminders and their description are
specified in the following table:
Information
displayed
The menu is divided into two sections: the operational menu (the unit in the ON mode) and the
service menu (unit in the OFF mode).
Operational Menu (Controller in ON Mode, see also sec.10.3.3 auf Seite 81)
Function name
Setting of heating
temperature
Setting of temperature
hysteresis
* Depending on the maximum heating temperature programmed in the controller.
** Factory settings are only the proposals for a setting. All the values depend on the size of heaters, the
capacity of the tank, user requirements etc.
Service Menu (Controller in OFF Mode, see also sec. 10.3.4 auf Seite 81)
Function name
Setting of heating
detection
DHW PAW-VP - Installation manual – 2020-05
Acoustic
Alarm diode
alarm
Flashing
Variable
Flashing
Variable
Flashing
Interrupted
Flashing
Interrupted
Parameter
Parameter
Description
Lack or failure of the sensor. Alarm switches off
automatically after repair of the failure.
Exceeding of the maximum temperature (75 °C,
95 °C, 110 °C) (Protect). Alarm is switched off after
manual deleting (entering the off switching mode).
Detection of lack of water (No Liquid). Alarm is
switched off after manual deleting (entering the off
switching mode).
Detection of lack of heating (No Heating). Alarm is
switched off after manual deleting (entering the off
switching mode).
Input of the external control EXT opened.
Controller stops the function of heating.
Setting ranges
15–160 °C*
1–10 °C*
Setting ranges
0 and 1
Electrical Heater
Factory setting
50 °C**
°C**
Factory setting
1
79
10