10
Electrical Heater
10.1 Models PAW-VP1000LDHW, PAW-VP750LDHW
The three above mentioned models are delivered with an additional electric heater as standard.
The heating is available according to the requirements of the customer.
For example as:
Anti-legionella heating, Additional heating, or both.
!
Important
The control of the electric heating must be carried out by the customer with electrical timer con-
troller or similar.
Heater for
PAW-VP1000LDHW
PAW-VP750LDHW
10.1.1 Electrical connection three phase 400 V
10.1.2 Parts and functions
C
A. Flange cover
B. Flange heater, thermostat, TR and anode
DHW PAW-VP - Installation manual – 2020-05
Voltage
400 V (L1 / L2 / L3 / N /PE / 50Hz)
400 V (L1 / L2 / L3 / N /PE / 50Hz)
400V
1 Flange cover
2 Flange heater, termostat, TR and anode
3 Gasket FD180
4 Termostat adjustment 35 to 85 degrees
1 Flange cover
2 Flange heater, termostat, TR and anode
400V
Symbol
R
1, 2, 3, 4, 5, 6
11R, 21S, 31T
TS
TR
U12, V22, W32
1C, 2C, 3C, 4C
L1, L2
B
D
C. Gasket FD180
D. Thermostat adjustment 35 to 85 degrees
Electrical Heater
Capacity
6 kW
6 kW
Description
Electric heating element
Heating elements contacts
Thermostat-out contacts
Thermostat safety device
Contact operated
Thermostat-in contacts
Supply contacts
Electric line connection
terminals
Ground
A
73