7. Remove the timing belt from the carriage driven pulley.
8. Remove the driven pulley assembly from the frame toward the arrowed
direction.
9. Remove the carriage guide shaft from the carriage unit.
Driven
Pulley
Timing Belt
Figure 4-15. Timing Belt Removal
Disassembly and Assembly
Figure 4-16. Driven Pulley Assembly Removal
Figure 4-17. Carriage Guide Shaft Removal
Disassembly Procedures
Carriage Unit
Carriage Guide Shaft