EPSON Perfection1200
5. Remove 2 screws (CP, M3x5) around the I/F connector located back of the
scanner.
6. Remove one gold screw (CBS, M3x4), and remove each cable from the
CR motor connector (CN5), carriage FFC connector (CN4) and power
supply unit connector (CN3).
7. Remove the main board.
CP(M3x5)
Figure 4-30. Main Board Removal (2) (USB)
Disassembly and Assembly
CR Motor
Connector
Figure 4-31. Main Board Removal (3) (USB)
Disassembly Procedures
Power supply
Carriage FFC
unit connector
Connector
CP (M3x4)
Figure 4-32. Main Board (USB)
Revision B