LG ARNH963K2A2 Installation Manual page 13

Hydro kit (for medium temperature)
Hide thumbs Also See for ARNH963K2A2:
Table of Contents

Advertisement

* WATER TANK & FLOOR HEATING INSTALLATION
1. Use the pump (1) with sufficient capacity to assure loss of overall water pressure and to supply
water to the
Hydro Kit
2. Install the shut-off valve (2) on both sides of the pump to clean and repair the pump.
3. Install the flexible joint (3) to prevent noise and vibration transferred from the pump.
4. Install the pressure gauge (4) to monitor the water pressure from water tank. (Option)
5. Install the expansion tank (5) to accommodate the water contracted or expanded from the
temperature difference and to supply the water.
6. After the installation of water pipe system is completed, open the water supply valve (6) and
supply the water.
7. When installing the water tank, insert the water tank temperature sensor (7) to measure the
temperature of the water inside the tank.
- For the water tank temperature sensor, use the sensor supplied on the product.
- When heating the floor, measure the temperature by using the remote controller or remote
temperature sensor (Separately sold).
8. Use the water tank (9) with the heat exchange coil (8) installed so that the heat can be exchanged
sufficiently inside the tank.
Installation of water tank
Installation of floor heating
.
shut-off valve (2)
Pump (1)
flexible joint (3):Optional
shut-off valve (2)
Pump (1)
flexible joint (3):Optional
water tank
temperature sensor (7)
Expansion tank (5)
Pressure gauge (4)
(Indirect heating type)
Water supply valve (6)
Expansion tank (5)
Floor heating coil
Pressure gauge (4)
(Radiator, FCU can be used)
Water supply valve (6)
Hydro Kit Installation Manual 13
Installation
Heat
exchange
coil (8)
water tank (9)

Advertisement

Table of Contents
loading

Table of Contents