Installation

Solar Thermal Kit

How to Install Solar Thermal Kit
Step 1. Check the diameter of pre-installed pipes. (symbol Ⓐ and Ⓑ)
Step 2. If the diameter of pre-installed pipes is different from diameter of solar thermal kit, it is
necessary to reduce or extend of pipeʼs diameter.
Step 3. After Step 2., connect the pipe and solar thermal kit.
Step 4. Connect solar thermal sensor to ʻCN_TH4ʼ(Red connector) of the Hydro Kit PCB.
If the water tank sensor is connected, disconnect the sensor from PCB first.
16 Hydro Kit
Solar Thermal Sensor
(less than 5 meter)
Water Tank Sensor
(less than 5 meter)
Water Out
Water In
Water Tank
3way valve
(Field Supply)
Water In
Water Out
Pump
(Field Supply)
Solar
Thermal
System
(Field Supply)
(Field Supply)
Solar
Collector