LG ARNH963K2A2 Installation Manual page 44

Hydro kit (for medium temperature)
Hide thumbs Also See for ARNH963K2A2:
Table of Contents

Advertisement

System Set-Up
Summary
Function
Test Run
Disable 3 Min. Delay
Remote Air Sensor Connection
Celsius/Fahrenheit Switching
Setting Temp. Selection
Auto Dry Contact
Address Setting
Override Setting
Water Pump Test Run
Setting Air Temp.
(cooling Mode)
Setting Leaving Water Temp.
(cooling Mode)
Setting Air Temp.
(Heating Mode)
Setting Leaving Water Temp.
(Heating Mode)
Setting Domestic Hot Water tank Water Temp.
(Domestic Hot Water Heating)
Setting Cut-off Temp.
(FCU Cooling Mode)
Setting outdoor Temp. range
(Weather-dependent operation)
Setting indoor air Temp. range
(Weather-dependent operation)
Setting leaving water Temp.
(Weather-dependent operation)
Setting control parameter
(Domestic Hot Water heating operation)
Setting control parameter
(Domestic Hot Water heating operation)
Setting Domestic Hot Water heating timers
Setting Water Flow Rate
Changing thermal on/off room air Temp.
Changing thermal on/off leaving water
Temp.
Program version
CAUTION:
There is no disinfection function in Hydro Kit.
So, external control equipment should be installed for disinfection function.
44 Hydro Kit
Example of Fuction Code Display
Function Code
Value #1
Default
Value #1
01:01
01 : Set
02:01
01
01 : NOT connected.
03:01
02 : connected.
01 : Celsius
04:01
02 : Fahrenheit
01 : Air Temp.
05:02
02 : Leaving water Temp.
01 : Auto Start OFF
06:02
02 : Auto Start ON
07:00
00 ~ FF
00 : Slave
08:00
01 : Master
09:00
01 : Set
24°C(75°F)~30°C(86°F)
11:030:018
: Upper Limit of setting range
12:024:006
20℃(68℉)~25℃(77℉)
: Upper Limit of setting range
12:024:016
24℃(75℉) ~ 30℃(86℉)
13:030:016
: Upper Limit of setting range
35°C(95°F)~50°C(122°F)
14:050:020
: Upper Limit of setting range
50°C(122°F)
15:050:040
: Upper Limit of setting range
22:016:000
16°C(60°F)~25°C(77°F)
10℃(50℉) ~ 20℃(68℉)
23:-10:015
: Upper Limit of setting range
20℃(68℉) ~ 30℃(86℉)
24:021:016
: Upper Limit of setting range
35°C(95°F)~50°C(122°F)
25:050:020
: Upper Limit of setting range
01℃(33℉) ~ 20℃(68℉)
28:005:050
: Temp. gap from Value #2
29:003:000
02℃(35℉) ~ 04℃(39℉)
2b:030
5 ~ 95 min (step: 5 min)
2b:180:020
0 ~ 600 min (step: 30 min)
2c:92
15~92 LPM
2E:00
00~03
2F:00
00~03
30:***
***
Value #2
Value #2
-
-
-
-
-
-
-
-
18°C(64°F)~22°C(71°F)
: Lower Limit of setting range
FCU is installed 06℃(42℉)~18℃(64℉)
: Lower Limit of setting range
FCU is not installed 16℃(42℉)~18℃(64℉)
: Lower Limit of setting range
16℃(60℉) ~ 22℃(71℉)
: Lower Limit of setting range
20°C(68°F)~34°C(93°F)
: Lower Limit of setting range
30°C(86°F)~40°C(104°F)
: Lower Limit of setting range
00 : FCU is installed
01 : FCU is NOT installed
-20℃(-4℉) ~ 05℃(41℉)
: Lower Limit of setting range
16℃(60℉) ~ 19℃(66℉)
: Lower Limit of setting range
20°C(68°F)~34°C(93°F)
: Lower Limit of setting range
40°C(104°F)~50°C(122°F)
00~01
-
20 ~ 95 min (step: 5 min)
-
-
-
-
*Temp. = Temperature
*Domestic Hot Water = Domestic Hot Water
Remark