Fan Control - Canon imageRUNNER ADVANCE C5500 Series Service Manual

Hide thumbs Also See for imageRUNNER ADVANCE C5500 Series:
Table of Contents

Advertisement

■ Count-up timing
Count-up timing differs according to the following:
• Print mode (1-sided/2nd side of 2-sided print, 1st side of 2-sided print)
• Delivery position (Finisher)
Delivery position
1
Host machine
2
When the Finisher is installed

Fan Control

■ Location of Fans
FM6
FM10
Circuit
code
FM1
Fixing Heat Exhaust Fan 1
FM2
Fixing Heat Exhaust Fan 2
FM3
Power Supply Cooling Fan
FM4
Process Cartridge Fan (Rear)
FM5
Fixing Cooling Fan (Front)
FM6
Fixing Cooling Fan (Rear)
FM7
Delivery Fan 1
FM8
Secondary Transfer Exhaust Fan
FM9
Delivery Fan 2
First Delivery Tray
Second Delivery Tray Second Delivery Sensor (PS42)
Third Output Tray
FM7
FM9
FM8
FM5
Name
Heat exhaust around the Fixing Assembly
Heat exhaust around the Fixing Assembly
To cool power supply.
Heat exhaust around the Process Cartridge
Cooling of the Fixing Assembly
Cooling of the Fixing Assembly
To cool the paper passing through the delivery area
To exhaust air around Secondary Pre-transfer Charging
Assembly
To cool the paper passing through the delivery area
1-sided print/2nd side of 2-sided print
First Delivery Sensor (PS41)
Third Delivery Sensor (PS43)
Finisher: Inlet Sensor (S1)
FM2
FM11
FM1
FM4
FM3
Role
152
Print mode
1st side of 2-sided print
Count-up timing
Duplex Paper Sensor
(PS38)
Error/Alarm code
E805-0000
E805-0001
E804-0000
E807-0000
-
-
E806-0000
E806-0002
E806-0001
2. Technology