The output response time is the time required by the analog output signal from starting the output change to when the change
is 90% complete. The time is extended or reduced depending on the variation of analog output. Note that the output response
time becomes longer (voltage output: 20s, current output: 10s) in the system with sudden output changes. In addition, the
output response time may be extended depending on the length of the cable used due to impedance of the cable.
The following figure shows the output response time of when the analog output is changed from the lower limit value (-10V) to
the upper limit value (10V) of the output range.
(1)
-32000
(3)
(2)
10V
90%
(18V)
-10V
(1): Digital value
(2): Analog output range (-10 to 10V)
(3): D/A conversion timing
(4): Output response time (maximum 20s)
APPX