Mitsubishi Electric FR-A800 Series Beginner's Manual page 78

Hide thumbs Also See for FR-A800 Series:
Table of Contents

Advertisement

Parameter list (FR-A800)
Param-
Name
eter
279
Brake opening current
Brake opening current
280
detection time
Brake operation time at
281
start
Brake operation
282
frequency
Brake operation time at
283
stop
Deceleration detection
284
function selection
Overspeed detection
frequency (Excessive
285
speed deviation
detection frequency)
286
Droop gain
Droop filter time
287
constant
Droop function
288
activation selection
Inverter output terminal
289
filter
Monitor negative output
290
selection
291
Pulse train I/O selection
Automatic acceleration/
292
deceleration
Acceleration/
293
deceleration separate
selection
UV avoidance voltage
294
gain
Frequency change
295
increment amount
setting
296
Password lock level
297
Password lock/unlock
298
Frequency search gain
Rotation direction
299
detection selection at
restarting
300
BCD input bias
301
BCD input gain
302
BIN input bias
303
BIN input gain
Digital input and analog
304
input compensation
enable/disable selection
Read timing operation
305
selection
A - 6
Setting Range
Initial Value
0–400 %
130 %
0–2 s
0.3 s
0–5 s
0.3 s
0–30 Hz
6 Hz
0–5 s
0.3 s
0, 1
0
0–30 Hz, 9999
9999
0–100 %
0 %
0–1 s
0.3 s
0–2, 10, 11
0
5–50 ms, 9999
9999
0–7
0
0, 1, 10, 11, 20, 21,
100 (FM type)
0
0,1 (CA type)
0, 1, 3, 5–8, 11
0
0–2
0
0–200 %
100 %
0, 0.01, 0.10, 1.00,
0
10.00
0–6, 99, 100–106,
9999
199, 9999
(0–5),
9999
1000–9998, 9999
0–32767, 9999
9999
0, 1, 9999
9999
Parameter for option FR-A8AX
Param-
Name
eter
Analog output signal
306
selection
Setting for zero analog
307
output
Setting for maximum
308
analog output
Analog output signal
309
voltage/current
switchover
Analog meter voltage
310
output selection
Setting for zero analog
311
meter voltage output
Setting for maximum
312
analog meter voltage
output
313
DO0 output selection
314
DO1 output selection
315
DO2 output selection
316
DO3 output selection
317
DO4 output selection
318
DO5 output selection
319
DO6 output selection
320
RA1 output selection
321
RA2 output selection
322
RA3 output selection
323
AM0 0V adjustment
324
AM1 0mA adjustment
Digital input unit
329
selection
RS-485 communication
331
station
RS-485 communication
332
speed
RS-485 communication
333
stop bit length/data
length
RS-485 communication
334
parity check selection
RS-485 communication
335
retry count
RS-485 communication
336
check time interval
RS-485 communication
337
waiting time setting
Communication
338
operation command
source
Communication speed
339
command source
Communication startup
340
mode selection
RS-485 communication
341
CR/LF selection
Appendix
Setting Range
Initial Value
Parameter for option FR-A8AY
Parameter for options
FR-A8AY, FR-A8NC
Parameter for option FR-A8AY
Parameter for option FR-A8AR
(Relay outputs)
Parameter for option FR-A8AY
(Analog/digital output)
Parameter for option FR-A8AX
(16 bit digital input)
0–31 (0–247)
0
3, 6, 12, 24, 48, 96,
192, 384, 576,
96
768, 1152
0, 1, 10, 11
1
0–2
2
0–10, 9999
1
0–999.8 s, 9999
0 s
0–150 ms, 9999
9999
0, 1
0
0–2
0
0–2, 10, 12
0
0–2
1

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fr-a820Fr-a840Fr-a842Fr-a846

Table of Contents