Mitsubishi Electric FR-A800 Series Beginner's Manual page 85

Hide thumbs Also See for FR-A800 Series:
Table of Contents

Advertisement

Appendix
Param-
Name
eter
C2
Terminal 2 frequency
(902)
setting bias frequency
C3
Terminal 2 frequency
(902)
setting bias
125
Terminal 2 frequency
(903)
setting gain frequency
C4
Terminal 2 frequency
(903)
setting gain
C5
Terminal 4 frequency
(904)
setting bias frequency
C6
Terminal 4 frequency
(904)
setting bias
126
Terminal 4 frequency
(905)
setting gain frequency
C7
Terminal 4 frequency
(905)
setting gain
C8
Current output bias
(930)
signal
,
C9
Current output bias
(930)
current
,
C10
Current output gain
(931)
signal
,
C11
Current output gain
(931)
current
,
C12
Terminal 1 bias
(917)
frequency (speed)
C13
Terminal 1 bias (speed)
(917)
C14
Terminal 1 gain
(918)
frequency (speed)
C15
Terminal 1 gain (speed)
(918)
Terminal 1 bias
C16
command (torque/
(919)
magnetic flux)
C17
Terminal 1 bias (torque/
(919)
magnetic flux)
Terminal 1 gain
C18
command (torque/
(920)
magnetic flux)
C19
Terminal 1 gain (torque/
(920)
magnetic flux)
Terminal 4 bias
C38
command (torque/
(932)
magnetic flux)
C39
Terminal 4 bias (torque/
(932)
magnetic flux)
Terminal 4 gain
C40
command (torque/
(933)
magnetic flux)
C41
Terminal 4 gain (torque/
(933)
magnetic flux)
C42
PID display bias
(934)
coefficient
C43
PID display bias analog
(934)
value
C44
PID display gain
(935)
coefficient
Frequency Inverters - Beginner's Guide
Setting Range
Initial Value
0–590 Hz
0 Hz
0–300 %
0 %
0–590 Hz
60/50 Hz
0–300 %
100 %
0–590 Hz
0 Hz
0–300 %
20 %
0–590 Hz
60/50 Hz
0–300 %
100 %
0–100 %
0 %
0–100 %
0 %
0–100 %
100 %
0–100 %
100 %
0–590 Hz
0 Hz
0–300 %
0 %
0–590 Hz
60/50 Hz
0–300 %
100 %
0–400 %
0 %
0–300 %
0 %
0–400 %
150 %
0–300 %
100 %
0–400%
0%
0–300 %
20 %
0–400 %
150 %
0–300 %
100 %
0–500.00, 9999
9999
0–300.0 %
20 %
0–500.00, 9999
9999
Param-
Name
eter
C45
PID display gain analog
(935)
value
Input voltage mode
977
selection
Parameter copy alarm
989
release
990
PU buzzer control
991
PU contrast adjustment
Operation panel setting
992
dial push monitor
selection
994
Droop break point gain
Droop break point
995
torque
997
Fault initiation
PM parameter
998
Simple
Simple
Simple
initialization
Automatic parameter
999
Simple
Simple
Simple
setting
Lq tuning target current
1002
adjustment coefficient
1003
Notch filter frequency
1004
Notch filter depth
1005
Notch filter width
1006
Clock (year)
1007
Clock (month, day)
Parameter list (FR-A800)
Setting Range
Initial Value
0–300.0 %
100 %
0, 1
0
10
100
10
100
0, 1
1
0–63
58
0–3, 5–14, 17–20,
22–35, 38, 40–45,
0
50–57, 61, 62,64,
67, 87–97, 100
0.1–100 %, 9999
9999
0.1–100 %
100 %
0–255, 9999
9999
0, 3003, 3103,
8009, 8109,9009,
0
9109
1, 2, 10–13, 20,
9999
21, 9999
50–150 %, 9999
9999
0, 8–1250 Hz
0
0–3
0
0–3
0
2000–2099
2000
101–131,
201–229,
301–331,
401–430,
501–531,
601–630,
101
701–731,
801–831,
901–930,
1001–1031,
1101–1130,
1201–1231
A - 13

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fr-a820Fr-a840Fr-a842Fr-a846

Table of Contents