Testing Fan Module Redundancy; Testing Hard Disk Redundancy - Huawei 5288 V5 Acceptance Manual

Table of Contents

Advertisement

5288 V5 Server
Acceptance Guide
Procedure
Expected Results
Test Result
Remarks

4.3.2 Testing Fan Module Redundancy

Case No.
Test Objective
Test Networking
Diagram
Prerequisites
Procedure
Expected Results
Test Result
Remarks

4.3.3 Testing Hard Disk Redundancy

Case No.
Test Objective
Test Networking
Diagram
Prerequisites
Issue 03 (2019-03-25)
1. Install two PSUs on the server, and connect cables to the PSUs.
2. Power on the server, and start the server OS.
3. Remove the power cable from one of the PSUs.
After the power cable is removed, the server is still operating
properly.
4.3.2
To verify that fan modules on the server work in redundancy
mode.
See section
2.1 Network
l The server is powered on.
l A Linux OS has been installed on the server.
1. Power on the server, and start the server OS.
2. Log in to the iBMC WebUI, and query the current fan speed.
3. Remove one of the fan modules, and check whether the OS is
still running properly.
4. Log in to the iBMC WebUI, and query the current fan speed.
After the fan module is removed, the server OS is still running
properly and the speed of the other fan modules increases for
better cooling.
4.3.3
To verify that hard disks on the server work in redundancy mode.
See section
The server is powered on.
Copyright © Huawei Technologies Co., Ltd.
Diagram.
2.1 Network
Diagram.
4 Test Cases and Records
19