The router deletes its main and backup next-startup configuration files and restores the factory-default
configuration.
The current mode is no password recovery. The configuration files will be
deleted, and the system will start up with factory defaults, Are you sure to
continue?[Y/N]Y
Setting...Done.
3.
When the EXTEND-BOOTWARE menu appears again, enter 0 to reboot the router.
The router starts up with the factory-default configuration.
4.
Configure a new console login password (see
new user privilege level passwords (see
5.
To make the settings take effect after a reboot, save the running configuration to the next-startup
configuration file.
[HP] save
Cooling system failure
When the environmental temperature of a module reaches or exceeds the high temperature threshold,
the fans rotate at full speed, and the following information appears on the configuration terminal:
%Dec
7 11:49:16:436 2011 HP DRVMSG/3/TEMP_WARNING:
Environment temperature is greater than warning upper limit in slot 0, index is 1.
#Dec
7 11:49:20:444 2011 HP DEVM/1/BOARD TEMPERATURE UPPER:
Trap 1.3.6.1.4.1.25506.8.35.12.1.16: chassisIndex is 0, slotIndex 0.0
%Dec 7 11:49:20:444 2011 HP DEVM/4/BOARD_TEMP_TOOHIGH: Board temperature is too high on
Chassis 0 Slot 0, type is HSR6602-XG.
After the router runs for a period of time, the environmental temperature of the router will drop below the
high temperature threshold, and the following information appears on the configuration terminal:
%Dec
7 11:50:11:436 2011 HP DRVMSG/3/TEMP_NOWARNING:
Environment temperature recovered from TEMP_WARNING in Slot 0, index is 1.
%Dec
7 11:50:11:436 2011 HP DRVMSG/3/TEMP_SYSNOWARNING:
System temperature recovered from TEMP_WARNING.
#Dec
7 11:50:13:244 2011 HP DEVM/1/BOARD TEMPERATURE NORMAL:
Trap 1.3.6.1.4.1.25506.8.35.12.1.17: chassisIndex is 0, slotIndex 0.0
%Dec 7 11:50:13:244 2011 HP DEVM/5/BOARD_TEMP_NORMAL: Board temperature changes to normal
on Chassis 0 Slot 0, type is HSR6602-XG.
When the environmental or CPU temperature of a module exceeds the critical temperature threshold, the
ALM LED of the router is red.
%Dec
7 11:17:01:436 2011 HP DRVMSG/3/TEMP_ALARM:
CPU temperature is greater than alarm upper limit in slot 0, index is 0.
To view the high temperature threshold and critical temperature threshold of each module, use the
display environment command.
To troubleshoot the cooling system failure: