Mitsubishi Electric 800 Series Instruction Manual page 50

Rs-485 interface board, rs-485 communication terminals
Hide thumbs Also See for 800 Series:
Table of Contents

Advertisement

Read/
Instruction
Item
write
Fault record
Read
H74 to H77
Operation
command
Write
HF9
(extended)
Operation
Write
HFA
command
Inverter status
Read
H79
monitor (extended)
Inverter status
Read
H7A
monitor
code
H0000 to HFFFF: Two latest fault records
(For details on fault record read data, refer to the data code in the list of fault
displays in the Instruction Manual (Detailed) of the inverter.)
Control input commands such as forward rotation signal (STF) and reverse rotation
signal (STR) can be set. (For the details, refer to
The states of the output signals such as forward rotation, reverse rotation and
inverter running (RUN) can be monitored. (For the details, refer to
Data description
b15
b8 b7
H74
Second fault in past
Latest fault
H75
Fourth fault in past
Third fault in past
H76
Sixth fault in past
Fifth fault in past
H77
Eighth fault in past
Seventh fault in past
Fault record display example (instruction code H74)
With the read data H30A0
(Last fault : THT)
(Present fault : OPT)
b15
b8 b7
0 0 1 1 0 0 0 0 1 0 1 0 0 0 0 0
Last fault
Present fault
(H30)
(HA0)
page
Number of
data digits
(Format)
b0
4 digits
(B.E/D)
b0
4 digits
(A,C/D)
55.)
2 digits
(A1,C/D)
4 digits
(B.E/D)
page
56.)
2 digits
(B.E1/D)
PARAMETER

4
49

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fr-a8ers

Table of Contents