4.4.11

Operation command

Instruction
Item
code
length
Operation
HFA
8 bits
command
Operation
command
HF9
16 bits
(extended)

The signal within parentheses ( ) is the initial status. The description changes depending on the setting of Pr.180 to Pr.189 (Input
terminal function selection).

The inverter run enable signal is in the initial status for the separated converter type.

JOG operation/automatic restart after instantaneous power failure/start self-holding selection/reset cannot be controlled over a network,
so in the initial status bit8 to bit11 are invalid. To use bit8 to bit11, change the signal by Pr.185, Pr.186, Pr.188, or Pr.189 (Input terminal
function selection). (A reset can be executed by the instruction code HFD.)
Bit
Description
b0: AU (Terminal 4 input selection)
b1: Forward rotation command
b2: Reverse rotation command
b3: RL (Low-speed operation command)
b4: RM (Middle-speed operation command)
b5: RH (High-speed operation command)
b6: RT (Second function selection)
b7: MRS (Output stop)

b0: AU (Terminal 4 input selection)
b1: Forward rotation command
b2: Reverse rotation command
b3: RL (Low-speed operation command)
b4: RM (Middle-speed operation command)
b5: RH (High-speed operation command)
b6: RT (Second function selection)
b7: MRS (Output stop)

b8: JOG (Jog operation selection)
b9: CS (Selection of automatic restart after
instantaneous power failure, flying start)
b10: STP (STOP) (Start self-holding
selection)

b11: RES (Inverter reset)
b12 to b15: -

[Example 1] H0002 Forward rotation
b15
0
0
0
[Example 2] H0800 low speed operation

(When Pr.189 RES terminal function selection is set to "0")

b15
0
0
0

Example
[Example 1] H02 Forward rotation
b7
b0
0
0
0
0
0
0
1
0
[Example 2] H00 Stop
b7
b0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
0
0
0
0
0
0
0
0
PARAMETER
b0
0
1
0
b0
1
0
0
4
55