Setting multiple parameters as a batch
Parameter settings are changed as a batch. Those include communication parameter settings for the Mitsubishi's
human machine interface (GOT) connection and the parameter setting for the rated frequency settings of 50 Hz/60 Hz
and acceleration/deceleration time.
Multiple parameters are changed automatically. Users do not have to consider each parameter number. (Automatic
parameter setting mode)
Pr.
Pr.
Name
group
Automatic
999
E431
parameter setting

The read value is always "9999".
Initial
Setting
value
range
1
Standard PID display setting
2
Extended PID display setting
GOT initial setting
10
(PU connector)
GOT initial setting
11
(RS485 terminals)
9999

GOT initial setting
12
(PU connector)
GOT initial setting
13
(RS-485 terminal)
20
50 Hz rated frequency
21
60 Hz rated frequency
9999
No action
Description
"Controller Type" in GOT: FREQROL 500/
700/800, SENSORLESS SERVO
"Controller Type" in GOT: FREQROL 800
(Automatic Negotiation)
PARAMETER
4
91