Beko BP109C User Manual page 27

Hide thumbs Also See for BP109C:
Table of Contents

Advertisement

Available languages

Available languages

1
Safety awareness
• Evacuate the refrigerant circuit.
• Purge the refrigerant circuit with nitrogen for 5 min.
• Evacuate again.
• Cut out the compressor and drain the oil.
Transportation, marking and storage for units that employ
flammable refrigerants
Transport of equipment containing flammable refrigerants
Attention is drawn to the fact that additional transportation
regulations may exist with respect to equipment containing
flammable gas. The maximum number of pieces of equipment or
the configuration of the equipment, permitted to be transported
together will be determined by the applicable transport regulations.
Marking of equipment using signs
Signs for similar appliances used in a work area generally are
addressed by local regulations and give the minimum requirements
for the provision of safety and/or health signs for a work location.
All required signs are to be maintained and employers should ensure
that employees receive suitable and sufficient instruction and
training on the meaning of appropriate safety signs and the actions
that need to be taken in connection with these signs.
The effectiveness of signs should not be diminished by too many
signs being placed together.
Any pictograms used should be as simple as possible and contain
only essential details.
27 / 220 EN