5.1.2 Locally Connecting the SMT PC to the BTS
This describes how to connect the Site Maintenance Terminal (SMT) PC to the ETH port on the
main control module of the BTS through an Ethernet cable. After they are connected, you can
operate and maintain the BTS on the SMT.
Prerequisite
The IP address and subnet mask of the SMT PC are set correctly. The IP address is in the same
network segment as the IP address (192.168.0.72/255.255.255.0) of the BTS.
Procedure
Step 1 Connect the SMT PC to the BTS through an Ethernet cable. One end is connected to the ETH
port on the main control board of the basic cabinet, and the other end is connected to the Ethernet
port on the SMT PC (usually a portable PC).
Step 2 Open the MS-DOS Prompt dialog box.
l
Step 3 Run ping 192.168.0.72 to verify the network connection between the computer and the BTS.
l
l
----End
5.1.3 Logging in to the BTS at the Local End
This describes how to log in to the BTS. You can run the SMT to directly log in to the BTS at
the local end.
Prerequisite
l
Issue 02 (2009-04-20)
If the PC is Windows 2000/XP operating system based, choose Start > Run on the SMT. In
the Run dialog box, run the cmd command. The MS-DOS Prompt dialog box is displayed.
NOTE
The IP address of the BTS is 192.168.0.72.
If the information similar to that in the following example is returned, the SMT PC and the
BBU can communicate normally.
Pinging 192.168.0.72 with 32 bytes of data:
Pinging 192.168.0.72 with 32 bytes of data:
Reply from 192.168.0.72: bytes=32 time=1ms TTL=253
Reply from 192.168.0.72: bytes=32 time=1ms TTL=253
Reply from 192.168.0.72: bytes=32 time=1ms TTL=253
Reply from 192.168.0.72: bytes=32 time=1ms TTL=253
Ping statistics for 192.168.0.72:
Packets: Sent = 4, Received = 4, Lost = 0 (0% loss),
Approximate round trip times in milli-seconds:
Minimum = 1ms, Maximum = 1ms, Average = 1ms
If the SMT PC and the BBU fail to communicate, the possible reason is as follows:
The GTMU is faulty.
–
The Ethernet cable is faulty, or its connectors are loose.
–
The Ethernet port on the SMT PC is faulty.
–
The BTS is resetting.
–
The IP address is incorrect.
–
The SMT PC is properly connected to the BTS.