Function Parameter
503
504
506
507
508
509
510
511
512
513
514
515
525
526
527
528
529
530
531
532
533
534
535
536
537
541
542
543
544
547
548
549
550
551
555
556
557
563
564
31
Name
Maintenance timer
Maintenance timer alarm output set time
Position detection hysteresis width
Rough match output range
Home position shift amount lower 4 digits 0 to 9999
Home position shift amount upper 4 digits 0 to 9999
Position detection lower 4 digits
Position detection upper 4 digits
Stopper control function selection
Stopper control torque limit
Stopper control switchover position lower
4 digits
Stopper control switchover position upper
4 digits
First positioning sub-function
Second positioning sub-function
Third positioning sub-function
Fourth positioning sub-function
Fifth positioning sub-function
Sixth positioning sub-function
Seventh positioning sub-function
Home position return selection
Home position return stopper torque
Home position return stopper duration
Position control terminal input selection
Position detection selection
Roll feed mode selection
Frequency command sign selection (CC-
Link)
Communication station number (CC-Link) 1 to 64
Baud rate selection (CC-Link)
CC-Link extended setting
USB communication station number
USB communication check time interval
Protocol selection
NET mode operation command source
selection
PU mode operation command source
selection
Current average time
Data output mask time
Current average value monitor signal
output reference current
Energization time carrying-over times
Operating time carrying-over times
Setting Range
0 (1 to 9998)
0 to 9998, 9999
0 to 32767
0 to 32767
0 to 9999
0 to 9999
0, 1, 10, 11, 12
0 to 200%
0 to 9999
0 to 9999
0, 1, 10, 11, 100, 101, 110, 111
0, 1, 10, 11, 100, 101, 110, 111
0, 1, 10, 11, 100, 101, 110, 111
0, 1, 10, 11, 100, 101, 110, 111
0, 1, 10, 11, 100, 101, 110, 111
0, 1, 10, 11, 100, 101, 110, 111
0, 10, 100, 110
2, 3, 4, 6
0 to 200%
0 to 10s
0, 1, 10, 11, 100, 101, 110, 111
0, 1, 2
0, 1
0, 1
0 to 4
0, 1, 12, 14, 18
0 to 31
0 to 999.8s, 9999
0, 1
0, 2, 9999
2 to 4, 9999
0.1 to 1.0s
0 to 20s
0 to 500A
(0 to 65535)
(0 to 65535)
Minimum
Initial
Customer
Setting
Value
Setting
Increments
1
0
1
9999
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1%
40%
1
0
1
0
1
10
1
10
1
10
1
10
1
10
1
10
1
10
1
4
0.1%
40%
0.1s
0.5s
1
0
1
0
1
0
1
0
1
1
1
0
1
0
1
0
0.1s
9999
1
0
1
9999
1
9999
0.1s
1s
0.1s
0s
Rated
0.01A
motor
current
1
0
1
0