Specification - Mitsubishi Electric FR-E700EX Manual

Sensorless servo
Hide thumbs Also See for FR-E700EX:
Table of Contents

Advertisement

Name (Model)
Line noise filter
FR-BSF01
(for drive units with small
capacities)
FR-BLF
Filterpack
FR-BFP2-K
crimping
terminals
Brake resistor
MRS type
39
 Outline dimension
FR-BSF01
110
95
2-φ5
65
33
 Using the option, the drive unit may conform to the Japanese guideline for reduction of harmonic emission.
 Specification
•Three-phase 200V power input model
Model FR-BFP2-
K
0.4
Permissible drive unit output
2.5
current (A) 
Approximate mass (kg)
1.3
Install a DC reactor on the DC side.
(93% to 95% of power supply
Power factor improving reactor
power factor under 100% load)
Common mode
Install a ferrite core on the input
choke
Noise filter
About 4mA of capacitor leakage
Capacitive filter
Protective structure (JEM1030)
 Select a capacity for the load (drive unit output) current to be equal
to or less than the permissible drive unit output current.
 The indicated leakage current is for one phase of the three-phase
three-wire star-connection power supply.
 The values in parentheses are calculated by applying 1 power
factor to the reference wave form in accordance with the
Architectural Standard Specifications (Electric Installation) (2013
revisions) in Japan.)
 Outline dimension
182
500
172
Round
1.25-4
φ4.3 hole
(Unit: mm)
Specifications, Structure, etc.
FR-BLF
φ7
130
85
160
180
Outline dimension drawing
<FR-BFP2-0.4K, 0.75K>
0.75
4.2
1.4
(94.4% )
side.
current 
Open type (IP00)
D2
Capacity
0.4K, 0.75K
(Note)1. The option can be installed to the back or to the side.
2. Above outline dimension drawings are examples. Dimensions differ by
model.
Control
Torque /
Resistor Model
Permissible
Duty
MRS120W200
150% torque
3%ED
MRS120W100
(Note)1. The temperature of the brake resistor becomes 200°C or more depending on the
operation frequency, care must be taken for installation and heat dissipation.
2. The brake resistor can not be used with the 0.1K and 0.2K.
3. Do not remove the jumper across terminal P/+ and P1 except when connecting a DC
reactor.
MCCB
Power
supply
Line noise
filter
(Note)1. Each phase should be wound at least 3 times (4 turns)
in the same direction.
(The greater the number of turns, the more effective
result is obtained.)
When using several line noise filters to make 4T or
more, wind the phases(cables) together. Do not use
different line noise filters for different phases.
2. When the thickness of the wire prevents winding, use at
least 4 in series and ensure that the current passes
through each phase in the same direction.
3. Can be used on the output side in the same way as the
input side. When using a line noise filter at the output
side, the filter body may heat up. Do not wind the cable
more than 3 times (4T) for each line noise filter installed
at the output side.
4. Use FR-BSF01 for the drive units with small capacities.
2
Thick wires (38mm
or more) can not be used. In such
cases, use the FR-BLF.
5. Do not wind an earthing (grounding) cable.
φ
2-
4.5 hole
Rating
plate
4.5
D1
D2
W2
D
W
W1 W2
H
H1
D
D1
68
30
19
218 208
60
30
(Unit: mm)
Applicable
Resistance
Permissible
Motor
Value
Power
Capacity
()
(W)
(kW)
200
15
0.4
100
30
0.75
Drive unit
R/L1
S/L2
T/L3
φ
2-
4.5 hole
4.5
W1
W2
W
D2
15
Thermal RelayType
(Mitsubishi
Product)
TH-N20CXHZ-0.7A
TH-N20CXHZ-1.3A

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mm-gkr