Identifying a Disk Drive
1.
Under the Systems tree in the left panel of HP 3PAR Management Console, select the storage
system to be serviced. The Summary tab should be displayed indicating the failed drive (see
Figure 31 (page
33)).
Figure 31 Summary Tab
WARNING!
The Physical Disks may indicate Degraded, which indicates that the disk drive
is not yet ready for replacement. It may take several hours for the data to be vacated; do not
proceed until the status is Failed. Removing the failed drive before all the data is vacated
will cause loss of data.
2.
On the Summary tab, select the Failed link in the Physical Disk row next to the red X icon
(
).
CAUTION:
If more than one disk drive is failed or degraded, contact your authorized service
provider to determine if the repair can be done in a safe manner, preventing down time or
data loss.
A filtered table displays, showing only failed or degraded disk drives (see
33)).
Figure 32 Filtered Table
The Alert tab displays a filtered Alert table showing only the critical alerts associated with disk
drives, where the alert details are displayed (see
NOTE:
The lower pane lists the alerts in a tabular fashion (you can see the highlighted alert
in
Figure 33 (page
34)). Highlighted alerts display their details in the pane above the list.
Figure 33 (page
34)).
Repairing a Disk Drive
Figure 32 (page
33