B Connecting to the Service Processor

You can connect the maintenance PC to the service processor (SP) either through a serial connection
or an Ethernet connection (LAN). When you are connected to the SP by a serial or Ethernet
connection, there are two SP user interfaces know as SPOCC and SPMAINT. Use either interface
to perform various administrative and diagnostic tasks.
NOTE:
Connecting to the SP through the LAN (Ethernet) requires establishing a Secure Shell
Session (SSH). If you do not have SSH, connect to the serial port of the SP.

Using a Serial Connection

To use a serial connection:
Procedure 1
1.
Locate the SP and attach the DB9 crossover serial adapter (P/N 180–0055) that is at the free
end of the blue Ethernet cable to the Serial port on your maintenance PC. Use a standard
Category 5 Ethernet cable with the appropriate RJ-45 to DB9 adapter to connect to the DB9
Serial port of SP.
2.
Insert a standard Category 5 Ethernet cable into the SP serial port with the DB9 crossover
serial to RJ45 adapter (P/N 180–0055).
Figure 48 HP DL320e SP Ports
#
1
2
3.
Power on the laptop.
Ports
Ethernet ports:
NIC1 (left)
NIC2 (right)
Serial port
Description
Use to establish an Ethernet
connection to the SP.
Use NIC1 for Public.
Use NIC2 for Private (SPOCC).
Use to establish a serial connection
to the SP.
Using a Serial Connection