Muffler Filter Manual Regeneration - Hitachi ZAXIS 135US-5B Operator's Manual

Hydraulic excavator
Table of Contents

Advertisement

Muffler Filter Manual Regeneration

Manual Regeneration Procedure
When the manual regeneration is needed, screen (1) as
shown in the right will be displayed. When this screen is
displayed, you need to perform the manual regeneration.
Before starting the manual regeneration, be sure to check
the following.
If the rear view camera is equipped on the machine and
the camera is enabled, screen (1) is displayed only when
the pilot control shut-off lever is in LOCK position. (Refer to
1-25)
 No person is present around the machine
 Keep flammable objects away from the muffler.
 Remaining fuel alarm does not light.
1. Park the machine in a safe place. Lower the front
attachment onto the ground.
2. Pull the pilot control shut-off lever to the LOCK position.
3. Set the engine control dial to slow idle.
4. Push the muffler filter regeneration switch (2).
5. When pushing the muffler filter regeneration switch (2),
screen (3) as shown in the right will be displayed and
the manual regeneration starts. Bar graph on the screen
indicates progress of the regeneration process.
d
CAUTION: The regeneration does not start unless the
pilot control shut-off lever is in the LOCK position and
the engine control dial is in slow idle. When touching
the pilot control shut-off lever or the engine control
dial during regeneration, the regeneration process is
aborted. When the process is aborted, start over again.
OPERATING THE MACHINE
5-12
1
MDAA-01-005EN
2
MDAA-01-330
2
MDAA-05-002
3
MDAA-01-006EN