6.3

dv/dt filter with Voltage Peak Limiter

6.3.1

Description

The dv/dt filter with VPL (Voltage Peak Limiter) consists of two components: The dv/dt
reactor and the voltage limiting network (Voltage Peak Limiter), which limits voltage peaks
and returns the energy to the DC link.
The dv/dt filters with Voltage Peak Limiter must be used for motors for which the voltage
strength of the insulation system is unknown or insufficient. Standard motors of the 1LA5,
1LA6 and 1LA8 series only require them at supply voltages > 500 V +10%.
The dv/dt filters with Voltage Peak Limiter limit the rate of voltage rise to values < 500 V/µs
and the typical voltage peaks at rated line voltage to the values below (with motor cable
lengths of < 150 m):
< 1000 V with U
< 1250 V with 660 V < U
Components
The Order Nos. of the individual components (dv/dt reactor and voltage limiting network) are
listed in the following table:
Table 6-7
dv/dt filter plus Voltage Peak Limiter
Warning
When a dv/dt filter with Voltage Peak Limiter is used, the pulse frequency of the Power
Modules or Motor Module must not exceed 2.5 kHz or 4 kHz. Setting a higher pulse
frequency could cause irreparable damage to the dv/dt filter.
Table 6-8
6SL3315-1TE32-1AA0
6SL3315-1TE32-6AA0
6SL3315-1TE33-1AA0
6SL3325-1TE33-1AA0
6SL3315-1TE35-0AA0
6SL3325-1TE35-0AA0
Chassis Power Units Liquid Cooled
SINAMICS S120 Equipment Manual, Edition 04/2007, 6SL3097-2AM00-0BP2
< 575 V
line
< 690 V.
line
dv/dt filter plus Voltage Peak Limiter, order numbers of individual components
6SL3000-2DE32-6AA0
6SL3000-2DE35-0AA0
6SL3000-2DH35-8AA0
6SL3000-2DH38-1AA0
6SL3000-2DH41-3AA0
Max. pulse frequency when a dv/dt filter is used in devices with a rated pulse frequency
of 2 kHz
Order no
Power
[kW]
110
132
160
160
250
250
dv/dt reactor
Supply voltage 380 V – 480 V
6SL3000-2DE32-6CA0
6SL3000-2DE35-0CA0
Supply voltage 500 V – 690 V
6SL3000-2DH35-8CA0
2 x 6SL3000-2DH38-1DA0
2 x 6SL3000-2DH41-3DA0
Output current at
pulse frequency of 2 kHz [A]
Connection voltage: 510 – 720 V DC
210
260
310
310
490
490
Motor-Side Power Components
6.3 dv/dt filter with Voltage Peak Limiter
Voltage limiting network
6SL3000-2DE32-6BA0
6SL3000-2DE35-9BA0
6SL3000-2DH35-8BA0
6SL3000-2DH38-1BA0
6SL3000-2DH41-3BA0
Max. pulse frequency when a
dv/dt filter is used
4 kHz
4 kHz
4 kHz
4 kHz
4 kHz
4 kHz
6-9