4. Maintenance and component replacement

4.3.2 Recover IP address using default IP address

The following procedure explains how to reboot the IF-240 so that is uses the default IP
address, subnet mask and TCP port number to be able to modify the IP address, subnet mask
and TCP port number when they are unknown and cannot be found. Following this
procedure, you are able to connect to the IF-240 with default parameters and then modify
parameters.
Material needed:
-
-
Step 1
Unscrew the 3 screws (A) and remove the cover. Use a Torx key size 10
Step 2
Place selector 2 in the "on" position (B)
Step 3
Disconnect and reconnect the power cable
(or switch off and switch on the power of the IF-240).
The IF-240 will use the following default parameters at startup:
IP: 192.168.0.64
SubnetMask: 255.255.255.0
TCP Port: 4001
32
Torx key size 10
(B)
Part Feeding 7.0 IF-240 Rev.5