In idle mode and when switched on, the charger consumes around 75 W of power.
A 1000 W heater is built into the charger for climate control inside the cabinet. This
keeps the components functioning within the charger's temperature and humidity
specifications and prevents condensation. This heater will switch on to full power when:
The temperature inside the cabinet gets below -20 °C.
•
•
The humidity gets above 90% relative humidity.
The heater switches off when:
•
The inside of the charger is heated to -12 °C
•
The humidity is below 80%.
4.7
Preventive maintenance
The charger must be inspected and serviced yearly by an ABB trained/certified
technician.
5
Compliance
Conformity with the relevant community harmonization legislation
Conformity with the following harmonized standard
Conformity to the metrology directives:
2 021 -01 -11
EMC Directive - No. 2014/30/EU
Low Voltage – No.2014/35/EU
RED Directive - No. 2014/53/EU
MID Directive – No. 2014/32/EU
EN 61000-6-3 (2007) + A1 ; EN 61000-6-4 (2007) + A1
Emission:
EN 61000-6-1 (2007) ; EN 61000-6-2 (2005)
Immunity:
EN 61851-1 (2011) + EN 61851-23 (2014)
LVD:
EN 62196-1 (2012)
EN 301 908-2 V11.1.2 (2017) ; EN 301 511 V12.5.1 (2017)
RED:
EN 300 330 V2.1.1 (2017) ; EN 50364 (2001)
EN 50470-1 (2006); EN 50470-3 (2006)
MID:
MessEG
MessEV
Product compliant to the REA DOCUMENT 6A