NEC Express5800 Series User Manual page 110

Hide thumbs Also See for Express5800 Series:
Table of Contents

Advertisement

Chapter 3 Setup
Option
Serial Port B Settings
Serial Port B
Serial B Base I/O
Serial B Interrupt
Console Redirection Settings
BIOS Redirection Port
Terminal Type
Baud Rate
Data Bits
Parity
Stop Bits
Flow Control
Continue C.R. after POST
Note
110
Parameter
Disabled
Enable or disable serial Port B.
[Enabled]
3F8h
Specify the base I/O address for serial port B.
[2F8h]
3E8h
2E8h
IRQ 4
Specify the interrupt for serial port B.
[IRQ 3]
[Disabled]
Specifying a setting other than Disabled enables direct
connections using the NEC ESMPRO Manager or hyper
Serial Port B
terminal from the specified serial port. If this feature is
enabled, the following setting menu items are displayed.
[VT100+]
Select the terminal type.
VT-UTF8
ANSI
9600
Specify the baud rate used for the interface with the
connected hardware console.
19200
57600
[115200]
7
Specify the data bit width.
[8]
[None]
Specify the parity bits.
Even
Odd
[1]
Specify stop bits
2
None
Specify the flow control method.
[Hardware RTS/CTS]
Disabled
Specify whether to continue the console redirection
[Enabled]
function after POST processing.
Parameters for Serial Ports A and B are contained in NEC ESMPRO Manager, Online
BMC Configuration Tool, and EXPRESSSCOPE Engine 3. However, setting for Serial Port
A is not reflected because this server does not have serial port A
Express5800/B120d, B110d User's Guide
2. Details of System BIOS
Descriptions
[
]: Factory settings

Advertisement

Table of Contents
loading

This manual is also suitable for:

Express5800/b120dExpress5800/b110dExpress5800 n8400-131fExpress5800 n8400-134fExpress5800 n8400-135fExpress5800 n8400-137f ... Show all

Table of Contents