5 - 2
SE4750 Integration Guide
SE4750 Command List (Continued)
Table 5-1
2
I
C Command Set
PICKLIST_MODE
PING
POWER_MODE
RD_SENSOR
RESET
TIME_TO_LOW_POWER
WR_SCRIPT
WR_SENSOR
Opcode
0x7B
Sets the rate of picklist frames.
0x7A
Used for test purposes.
0x5F
Places the SE4750 in low power mode.
0x51
Reads the Aptina AR0134 registers.
0x57
Returns engine components to a default state.
0x75
Sets the length of time the SE4750 is idle before
entering low power mode.
0x76
Programs more than one SE4750 command into one
script.
0x50
Writes to the Aptina AR0134 registers.