5 - 10 SE4750 Integration Guide
SE4750 Command and Response Formats (Continued)
Table 5-3
Function
POWER_MODE
ILLUMINATION_POWER_LEVEL
ENTER_BOOTLOADER
GET_PARAM
(see Note 3 and
Table
IMAGE_CAPTURE_MODE
AUTO_POWER_REDUCTION
TIME_TO_LOW_POWER
WR_SCRIPT (Note 3)
EXECUTE_SCRIPT
GET_EXTENDED_STATUS
PING
PICKLIST_MODE
Notes:
1. Every command has a 1 byte checksum (last byte of command). See Command Checksum on page 5-4.
2. Every response has a 1 byte status code immediately following the Opcode. See Response Status Code
on page 5-4.
3. These commands/responses have a variable length data field indicated by (A):Array. See Table 5-4 on
page 5-11 for the length of the field based on the param number.
Op
0x5F
(B)
0x00=Full*
0x01=Low
0xF0
(B)
Lowest = 1
Highest Power Level = 18
Default = 13
0x91
(A) Signature (3 bytes:
0xAA, 0x50, 0x5F)
0x70
(W) Param#
5-4)
0x73
(B)
0x00 = Continuous
0x01 = Snapshot
0x74
(B)
0x00=Disabled
0x01=Enabled
0x75
(B)
0x01* - 0x0A = 10-100 ms, 10 ms
increments
0x0B - 0x14 = 100-900 ms, 100 ms
increments
0x15 - 0xFF = 1s - 235 s, 1 s increments
0x00 = 5 ms
0x76
(B) Script#
0x77
(B) Script#
0x79
-
0x7A
-
0x7B
(B) #Picklist-Frames
SE4750 Command
Note1
SE4750 Command Data
(A) Script Data
(B) #Frames
SE4750 Response
SE4750 Response
Op
Note2
Data
0x5F
-
0xF0
-
0x91
0x70
(W) Param#
(A) Param
Data
(Note 3)
0x73
-
0x74
-
0x75
-
0x76
-
0x77
-
0x79
0x7A
0x7B