The programming in the following table sets up 3% slip from 10 to 60 Hz with a 25% deadband.
Programming
Parameter
F320 Drooping Gain 100%
F321 Speed at Drooping Gain 0%
F322 Speed at Drooping Gain 100%
F323 Drooping Insensitive Torque Band
If instabilities occur as a result of drooping, refer to the document/application note titled 'Drooping
(advanced)' which covers items such as droop filtering, load inertia, and drooping references.
For additional assistance, please contact Toshiba Adjustable Speed Drive Marketing Dept. at (800) 872-2192
efesotomasyon.com -Toshiba inverter,drive,servo,plc
Program Feedback Parameter
Program Feedback Parameter
Program Feedback Parameter
Program Feedback Parameter
How to get there
Drooping Control
Drooping Control
Drooping Control
Drooping Control
New Value
3%
10.0 Hz
60.0 Hz
25.0%