Category 1 emergency stop for ACS800-07/U7
(+Q952, R6, R7, R8)
What this chapter contains
This chapter describes the category 1 emergency stop function (+Q952). The
chapter includes operation, user settings and example circuit diagrams.
To which drives this chapter applies
The chapter applies to the following drives
Drive type
ACS800-07
ACS800-U7
when equipped with one of the following application programs:
Option code
-
+N651
+N666
+N669
The parameter references in the chapter apply to ACS800 Standard Application
Program. For the other application programs, check correct parameters.
Description
Category 1 definition
IEC/EN60204-1 defines category 1 emergency stop as a controlled stop with the
power to machine actuators available to achieve the stop and then removal of power
when the stop is achieved.
Implementation of category 1 stop in ACS800 in brief
After the emergency stop command has been given, the drive first decelerates the
motor to a standstill according to a preset ramp time. Then, the main contactor is
switched off.
Frame sizes
Option codes and descriptions
R6, R7, R8
+F250+Q952+(D150 or D151) = line contactor + category 1
emergency stop + brake chopper (external resistor) or
brake chopper and resistor
ACS800 application program
Standard
Master/Follower
Extruder Control
Centrifuge Control
Category 1 emergency stop for ACS800-07/U7 (+Q952, R6, R7, R8)
41