Motor Modules in booksize C/D-type format
3.2 Motor Modules with internal air cooling
Figure 3-17
Figure 3-18
Figure 3-19
Derating characteristics for Motor Modules in booksize C/D-type format
Note
For information about derating depending on ambient temperature and installation altitude,
please refer to Chapter "System data" (Page 35).
64
S6 duty cycle with initial load for a duty cycle duration of 60 s
Duty cycle with 60 s overload for a duty cycle duration of 300 s
Duty cycle with 30 s overload for a duty cycle duration of 300 s