Electrolux EWM09312 Service Manual page 11

Hide thumbs Also See for EWM09312:
Table of Contents

Advertisement

Position 9
Drain, calibration of
analogue pressure
switch and spin.
Position 10
Drum position
Position 11
Reading/Deleting the last
alarm
(*)
In most cases, this time is sufficient to check the heating. However, the time can be increased by repeating
the phase without draining the water: pass for a moment to a different phase of the diagnostic cycle and
then back to the heating control phase (if the temperature is higher than 80°C, heating does not take
place).
(**) The check at the maximum speed occurs without control of the A.G.S. (Unbalancing Control Algorithm) and
no garments must be inside the
Technical Support - A.D.L.
Purpose of the test:
Components activated:
Working conditions:
LCD display
Purpose of the test:
Components activated:
Working conditions:
LCD display
Purpose of the test:
Components activated:
Working conditions:
LCD display
appliance.
To check the correct operation of the spin cycle
drain pump and calibrate the analogue pressure
switch.
• Door safety interlock
• Drain pump
• Motor up to 650 rpm then at maximum spin
speed (**)
• Door closed
• Water level lower than anti-boiling level for
spinning
Drum speed in rpm/10
To check the correct position of the drum via DSP
• Drum rotation motor.
• Door fastening device.
• Drum position sensor DSP.
• Door closed.
Reading/Deleting the last alarm
11/70
-------------
-------------
599 74 23-12 Rev.00

Advertisement

Table of Contents
loading

Table of Contents