Description
Drain filter clogged
(drain phase too long)
Overdosing of detergent
(too much foam during drain
phases)
Aqua control system intervention
Water fill pressure too low, no
signal from flowmeter and
electronically controlled valve is
open
Unbalanced load
Reset
Power supply frequency of
appliance outside the limits
Supply voltage too high
Supply voltage too low
0Watt relay malfunction
Inconsistency between FCV relay
(in the main board) and safety
"sensing" circuit
Safety sensing circuit faulty
(wrong input voltage to
microprocessor)
Technical Support - A.D.L.
Possible fault
• Drain filter clogged/dirty.
• Drain hose blocked/kinked/too high.
• Excessive detergent dosing.
• Drain hose kinked/blocked.
• Drain filter clogged/dirty.
• Water leaks onto base frame.
• Aqua control device faulty.
• Tap closed.
• Water fill pressure too low.
• Final spin phases skipped.
• If it continues, replace the main board
• Problem with the power supply network (incorrect/disturbed).
• Main circuit board faulty.
• Problem with the power supply network (incorrect/disturbed).
• Main circuit board faulty.
• Problem with the power supply network (incorrect/disturbed).
• Main circuit board faulty.
• Main circuit board faulty.
• Faulty wiring.
• Main circuit board faulty.
• Main circuit board faulty.
Warning displayed at the end of cycle.
Warning displayed after 5 attempts or by the
specific LED.
Appliance drains
Wait for nominal frequency conditions
Wait for nominal voltage conditions.
Wait for nominal voltage conditions.
Safety drain cycle
Cycle stops with door open
Safety drain cycle
Cycle stops with door open
21/70
Action
Machine status
START/RESET
RESET
ON/OFF
RESET
----------------
RESET
----------------
START/RESET
----------------
ON/OFF
ON/OFF
ON/OFF
ON/OFF
----------------
RESET
RESET
RESET
599 74 23-12 Rev.00