8.2 Main circuit board connectors

J9
Serial Interface:
J9-1 ASY_IN
J9-2 ASY_OUT
J9-3 +5V
J9-4 GND
J8
J8-1 DSP (signal)
J8-2 GND
J8-3 DSP
J13
J13-1 Wash solenoid valve (Triac)
J13-2 --------
J13-3 Solenoid valves (line)
J13-4 Solenoid valves (line)
J13-5 --------
J13-6 Pre-wash solenoid valves
(Triac)
J5
J5-1 Door lock (Sensing Line)
J5-2 Door lock (Line)
J5-3 Door lock (Triac)
J5-4 Drain pump (Line)
J5-5 Drain pump (Triac)
Technical Support - A.D.L.
J7
J7-1 Analogue pressure switch (+5V)
J7-2 Analogue pressure switch (GND)
J7-3 Analogue pressure switch (signal)
J7-4 NTC temperature probe
J7-5 NTC temperature probe
J10
Communication with display board:
J10-1 Vee 12V
J10-2 5V
J10-3 Rx/Tx
GND
J10-4
J11
J11-1 Motor (stator - half range)
J11-2 Motor (stator full range)
J11-3 Motor (rotor)
J11-4 Motor (rotor)
J11-5 Motor (Triac)
J11-6 Motor (tachometric generator)
J11-7 Motor (tachometric generator)
J14
J14-1 Aqua control sensor
J14-2 Aqua control sensor line (neutral)
J6
J6-1 heating element (Line Relay)
J6-2 heating element (Neutral Relay)
J4
J4-1 line (neutral)
J4-2 line
67/70