Measure the resistance
value of the heating
element (Ω) between
terminals J6-1 ÷ J6-2 of the
wiring connector
-(see Fig. 4)-
Is the value correct?
(28÷31Ω for 230V/1750W)
Y
E
S
Replace the circuit board
and repeat the diagnostic
cycle to check for any
further alarms.
Fig.13
28÷31Ω 230V 1750W
Technical Support - A.D.L.
E69: Washing heating element damaged
Measure the resistance
value directly on the
terminals of the heating
element
(detach the connectors)
NO
-(See fig 13)-
Is the value correct?
(28÷31Ω for 230V/1750W)
Y
E
S
Check/replace the wiring and repeat the diagnostic cycle to check
Fig. 4
General earthing
connection
Washing heating
element
!
Check that all the connectors are correctly inserted
NO
for any further alarms.
28÷31Ω 230V 1750W
If there are burns on the circuit board,
!
54/70
Replace the heating
element and repeat the
diagnostic cycle to check
for any further alarms.
MAIN CIRCUIT
BOARD
see page 68