Panasonic HUSSMANN SMED153 Installation Manual page 35

Medium temperature remote cabinet semi vertical display door cabinet
Table of Contents

Advertisement

TROUBLESHOOTING
6.1
TROUBLESHOOT TABLE
ISSUE
Products are freezing up
Cabinet exterior is
sweating
Door Alignment is out
Lights are not working
PAGE 35
POSSIBLE REASON
Store condition is too cold compared to
design climate class 3
Case evaporator pressure is lower than
specification.
Ambient moisture leakage
Store humidity is high
Insufficient ventilation
Icon Controller settings (if fitted)
Case SST
Case is not Level
No power supply
Light Components maybe faulty or
operating in fail safe
Lamp failed
REMEDIAL ACTION
Check store climate control is operating
correctly. If store condition cannot be
lifted, then adjust cabinet evaporator
pressure and defrost strategy to suit.
Adjust cabinet evaporator pressure
to suit.
Check any sealing issue
Check store climate control is operating
correctly.
Check case ventilation under and
at rear of the case. A fan kit may be
needed, please see your refrigeration
service provider for details.
Check settings
SST set too low
Refer to page 14 for levelling
information.
Check supply is "on" and light switch is
working.
Call your refrigeration service provider
to check and replace is necessary
Replace lamp
SMED SEMI VERTICAL - HUSSMANN

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hussmann smed163

Table of Contents